Underfloor heating calculator

The calculator needs JavaScript. The worked example, formula and figures below show exactly how it works, so you can do the sum yourself. A guide, not advice. Check your supplier's or maker's figures before ordering.

Short answer

Worked example

Worked example inputs
You enterValue
SystemWet (water pipes)
Heated floor area15 m²
Room heat loss1,200 W
Floor surface temperature29 °C
Room temperature20 °C
Pipe spacing150 mm
Tails to the manifold0 m
Output coefficient8.92 W/m²K
Output exponent1.1

100.0 W/m² (1500 W); 100 m of pipe

  • Limit not yet confirmed Floor surface temperature: 29 °C The limit for this check hasn't been confirmed yet: check the source. UK-wide: BS EN 1264 (maximum floor surface temperature). Check with the source.
  • Within the guidance Floor output vs room heat loss: 1,500.109 W UK-wide: BS EN 1264 (design heat output to cover the room heat loss). Check with the source.
Worked example results
ResultValue
Output per m²100 W/m²
Output for the room1,500 W (5,119 BTU/h)
Pipe needed100 m
Show the working
  1. Output: 8.92 × (29 − 20)^1.1 = 100 W/m²
  2. Room: 100 W/m² × 15 m² = 1,500 W
  3. Pipe: 15 m² ÷ 0.15 m (150 mm spacing) + 0 m tails = 100 m
  4. Heat loss to meet: 1,200 W

How it works

  1. Wet output q (W/m²) = 8.92 × (floor surface temperature − room temperature)^1.1 (BS EN 1264 basic characteristic)
  2. Room output (W) = q × heated floor area
  3. Pipe (m) = heated floor area ÷ pipe spacing + tails to the manifold; loops = pipe ÷ the maker's longest loop, rounded up
  4. Electric: output (W) = area × mat W/m²; current (A) = W ÷ supply voltage

The floor finish (its tog or R-value) doesn't change the output at a given surface temperature, but a thicker or more insulating finish needs warmer water to reach it.

Electric mats need their own circuit with RCD protection; bathrooms have extra rules (BS 7671 Section 701).

Our default (adjustable)

These are typical planning figures and our own allowances, not facts about your product. Change any of them in the calculator to match your bag, pack or tin.

FigureOur default (adjustable)KindSource
Output coefficient8.92 W/m²K^nOur assumption
Not yet checked against the source
Our choice: change it to suit your job
Coefficient in q = 8.92 × (θfloor − θroom)^1.1, brief v2 H6 (BS EN 1264 characteristic). Brief says "Researcher verifies".
Output exponent1.1 Our assumption
Not yet checked against the source
Our choice: change it to suit your job
Exponent in q = 8.92 × (θfloor − θroom)^1.1, brief v2 H6 (BS EN 1264 characteristic). Brief says "Researcher verifies".
Maximum floor surface temperatureTo be confirmed from the sourceRegulation or HSE figure
BS EN 1264 (maximum floor surface temperature, occupied zone)
Not yet checked against the source
Source to be added by the Researcher
Brief v2 H6: max floor surface temperature is a limit from the BS EN 1264 explainer. Researcher to fill the value and cite the clause.
Supply voltage230 VOur assumption
Not yet checked against the source
Our choice: change it to suit your job
UK nominal single-phase supply voltage (brief v2 E2). Researcher to cite the statutory source.

Regulations and standards

  • BS EN 1264 (floor heating output and surface temperature)
  • BS 7671:2018+A4:2026 (electric mats)

Explained: BS EN 1264 (underfloor heating), BS 7671 (the IET Wiring Regulations).

Our checks use the guidance for England unless a badge says otherwise. Wales, Scotland and Northern Ireland have their own rules: check the source for where you live.