Solar PV system size calculator

The calculator needs JavaScript. The worked example, formula and figures below show exactly how it works, so you can do the sum yourself. A guide, not advice. Check your supplier's or maker's figures before ordering.

Short answer

Worked example

Worked example inputs
You enterValue
Start fromMy roof area
Roof facesSouth face: usable area 20 m²
Area of one panel1.95 m²
Panel power430 W
kk: kWh per kWp for your roof850 kWh/kWp
Shading factor1 ×

10 panels, 4.30 kWp: about 3,655 kWh a year (indicative)

Worked example results
ResultValue
Panels that fit10
System size4.3 kWp
Estimated generation a year (indicative)3,655 kWh
kk used850 kWh/kWp
Panels by roof face
Roof faceUsable area (m²)Panels
South face2010
Show the working
  1. South face: 20 m² ÷ 1.95 m² = 10.26, rounded down = 10 panels
  2. System size: 10 panels × 430 W ÷ 1000 = 4.3 kWp
  3. Generation: 4.3 kWp × 850 kWh/kWp × 1 = 3,655 kWh a year (your kk)

How it works

  1. Panels per face = usable area ÷ panel area, rounded down (only whole panels fit)
  2. kWp = panels × panel power (W) ÷ 1000
  3. Generation (kWh a year) = kWp × kk × shading factor (MCS MIS 3002 method)

We don't estimate savings, payback or export payments: they depend on your tariff and how you use the power.

The inverter is sized by the installer to the array and the maker's data; an MCS installer also handles the DNO notification.

Indicative only: an MCS installer surveys the roof and gives the generation estimate.

Our default (adjustable)

These are typical planning figures and our own allowances, not facts about your product. Change any of them in the calculator to match your bag, pack or tin.

FigureOur default (adjustable)KindSource
Shading factor1 ×Our assumption
Not yet checked against the source
Our choice: change it to suit your job
brief v2 E7 (PV1): shading factor 1.0 = no shading. Researcher to cite the MCS shading method.

Regulations and standards

  • MCS MIS 3002 and MGD003 (estimating PV generation)
  • BS 7671:2018+A4:2026 Section 712 (solar photovoltaic power supply systems)

Explained: BS 7671 (the IET Wiring Regulations), Approved Document P (electrical safety).

The MCS method and BS 7671 are used across the UK. Planning rules for panels differ between England, Wales, Scotland and Northern Ireland.

Reference tables this calculator reads
TableClauseNationsStatus
kWh per kWp (kk) by postcode zone, orientation and pitchMCS MIS 3002 / MGD003 irradiance data set (Researcher to confirm whether the tables may be reproduced, brief v2 E7 and §16 Q1)UK-wide0/0 values entered